Kestrel 4300 Pocket Weather Meter (Free Shipping Online Only)

Kestrel 4300 Pocket Weather Meter (Free Shipping Online Only)

Price: $489.00  $489.00

Add to Cart:

  • Model: k4300
  • Shipping Weight: 0.5kgs

Please Choose:




***Free Shipping only when ordered online***


Improve results when doing surface coating and concrete pouring. Ensure worker and equipment safety by knowing accurate local weather conditions.

For years construction professionals have been using Kestrel Meters to monitor the weather on the job site. Now NK has partnered with industry experts to develop a customized Kestrel instrument for construction professionals who place concrete.


Calculates Evaporation Rate

The new Kestrel 4300 Construction Weather Tracker measures and displays evaporation rate — a function of relative humidity , temperature and wind speed . Evaporation rate is a critical environmental indicator that concrete contractors use to ensure they avoid plastic shrinkage cracks in concrete installations especially concrete flatwork. Plastic shrinkage cracks occur when the surface of the concrete dries too quickly and shrinks before the bed has cured enough to resist cracking. This is especially relevant in specialty applications like decorative concrete, Ready Mix Concrete (RCM) and Tilt-up concrete.

Helps Prevent Plastic Shrinkage Cracks

Plastic shrinkage cracks can be prevented by properly assessing the weather and the fresh concrete conditions. Previously, construction contractors used a Kestrel Meter to measure the relevant conditions, then referenced an American Concrete Institute chart to calculate the evaporation rate. The new Kestrel 4300 Construction Weather Tracker does the work for them! The user simply enters the concrete temperature (obtained via an infrared thermometer or probe thermometer*) and the 4300 calculates the evaporation rate instantly. In addition to evaporation rate, the Kestrel 4300 remains the perfect rugged all-purpose construction weather tool, measuring and logging the following relevant weather conditions right where the workers and equipment are operating.


For maximum accuracy when measuring the evaporation rate:

Measure the concrete temperature via an infrared or probe thermometer

Enter the concrete temperature into the Kestrel

Position the unit facing into the wind, 20 inches above the concrete

Shade the Kestrel's thermistor (temperature sensor) so it is not in direct sunlight

For the best accuracy, use the Kestrel's convenient averaging mode to average the evaporation rate over the recommended 6-10 seconds.



Documents Work Conditions

Many construction applications require documentation of conditions, which is quick and easy with the Kestrel PC Interface and accompanying software . Use the 4300's 1800 data-point log to document that work was done during the appropriate conditions, then upload the data to a PC with the Kestrel PC Interface. The Kestrel Communicator software makes long-term storage, in-depth analysis and detailed charting of stored data a breeze.

Kestrel's Mini Tripod is a great companion for the 4300—it measures 15 inches tall, positioning the Kestrel 4300 20 inches above the concrete, which is ideal for measuring the conditions that contribute to plastic shrinkage cracks.


Every Kestrel is individually calibrated to NIST-traceable standards and comes with a free Certificate of Conformity . Individual NIST certificates and recalibration are also available.


Kestrel 4300 Measures

Evaporation rate

Relative humidity

Wind speed

Temperature

Dewpoint

Barometric pressure

Heat stress index

Wet bulb temperature

Windchill

Altitude

Density altitude

 



Kestrel 4300 Features

Waterproof and floats

Backlight for low light conditions

Data logger (automatic and manual)

Customizable data storage – 3600 data points

Multi-Function 3-line display

Convenient averaging mode

Data charting

Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit.

User-replaceable impeller

Flip-top impeller cover

Upload to a computer (with optional interface)

Five languages (English, French, Spanish, German, and Italian)

US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074

5-year warranty

Assembled in the USA



Kestrel 4300 Includes

Soft carry pouch

Neck lanyard

Batteries – 2 AAA

Kestrel Certificate of Conformity

Measurement
Response Time
UnitsOperational RangeResolutionAccuracy
(+/-)
Specification Range
Wind Speed
(Air Velocity)
1 second
m/s0.4 to 60.0 m/s0.1Larger of 3% of reading or least significant digit0.4 to 40.0 m/s
ft/min59 to 11,948 ft/min159 to 7877 ft/min
km/h1.0 to 218.0 km/h0.11.0 to 144.0 km/h
mph0.8 to 135.0 mph10.8 to 89.0 mph
knots0.6 to 118.3 kt0.10.6 to 78.0 kt
Beaufort0 to 12 B0.10 to 12 B
1 inch diameter impeller with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may cause destruction of impeller. Replacement impeller (NK PN-0801) may be field-installed without tools (US Patent 5,783,753).

Temperature
1 second

°F-49.0 to 257.0 °F0.11.8 °F-20.0 to 158.0 °F
°C-45.0 to 125.0 °C0.11.0 °C-29.0 to 70.0 °C
Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible.
Relative Humidity
1 minute
%RH0.0 to 100.0 %0.13.0 %RH5.0 to 95.0 % non-condensing
Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.) Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802).
Evaporation Rate
1 second
lb/ft2/hr0.00 to 1.00 lb/ft2/hr0.01Typical: ±0.02 lb/ft2/hr0.00 to 1.00 lb/ft2/hr
kg/m2/hr0.00 to 5.00 kg/m2/hr0.01Typical: ±0.1 kg/m2/hr0.00 to 5.00 kg/m2/hr
Calculated from the primary measurements of wind speed, air temperature, relative humidity and concrete temperature. Requires user measurement and entry of concrete temperature obtained with an accurate IR or probe thermometer (°F or °C, not included with Kestrel 4300). For maximum accuracy, readings should be taken 20 inches above pour surface with the thermistor shaded, and averaged for 6-10 seconds using built-in averaging function. Maximum accuracy: ±0.06 lb/ft2/hr or ±0.3 kg/m2/hr.
Pressure
1 second (mb & PSI 4000 model only)
inHg8.86 to 32.48 inHg0.010.05 inHgAt 77.0 °F, <19,700 ft
hPa / mb300.0 to 1100.0 hPa / mb0.11.5 hPa / mbAt 25.0 °C, <6,000 m
PSI4.4 to 16.0 PSI0.10.1 PSIAt 77.0 °F, <19,700 ft
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error beyond specified temperature, +/- 0.09 inHg / 3.0 hPa. Calibration drift typically -0.03 inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory or in field.
Altitude
1 second
ft-6000 to 30000 ft150 ftAt 77.0 °F, <19,700 ft. Max error +/- 98 ft
m-2000 to 9000 m115 mAt 25.0 °C, <6,000 m. Max error +/- 30 m
Temperature compensated pressure (barometric) altimeter.
Wind Chill
1 second
°F0.7 to 135.0 MPH, -49.0 to 257.0 °F0.11.8 °F1.8 to 89.0 mph, -50.0 to 50.0 °F
°C0.4 to 60.0 m/s, -45.0 to 125.0 °C0.11.0 °C0.4 to 40 m/s, -45.6 to 10.0 °C
Calculated from the primary measurements of wind speed and temperature. Utilizes the NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground. (Specification temperature limits established by WCT Tables.)
Heat Index
1 minute
°F0.0 to 100.0 %RH, -49.0 to 257.0 °F0.13.6 °F70.0 to 130.0 °F, 0 to 100% RH
°C0.0 to 100.0 %RH, -45.0 to 125.0 °C0.12.0 °C21.1 to 54.4 °C, 0 to 100 %RH
Calculated from the primary measurements of temperature and relative humidity. Utilizes the NWS Heat Index (HI) tables. (Specification temperature limits established by HI tables.)
Dewpoint
1 minute
°F0.0 to 100.0 %RH, -49.0 to 257.0 °F0.13.6 °F-20.0 to 158.0 °F, 20.0 to 95.0% RH
°C0.0 to 100.0 %RH, -45.0 to 125.0 °C0.12.0 °C-29.0 to 70.0 °C, 20.0 to 95.0 %RH
Calculated from the primary measurements of temperature and relative humidity. Temperature to which the air would need to be cooled at a constant pressure to become saturated.
Wet Bulb Temperature
1 minute
°F-49.0 to 257.0 °F, 0.0 to 100.0 %RH, 8.86 to 32.48 inHg0.13.6 °F32.0 to 100.0 °F, 5.0 to 95.0% RH, 8.86 to 32.48 inHg, <19700 ft
°C-45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa0.12.0 °C0.0 to 37.8 °C, 5.0 to 95.0 %RH, -2000.0 to 9000.0 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Temperature indicated by a wet bulb psychrometer.
Density Altitude
1 second
ft-49.0 to 257.0 °F, 0.0 to 100.0 % RH, 8.86 to 32.48 inHg124632.0 to 100.0 °F, 5.0 to 95.0 %RH, 8.86 to 32.48 inHg, <19700 ft
m-45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa1750.0 - 37.8 °C, 5.0 to 95.0 %RH, -2000 to 9000 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Air density converted to equivalent sea level elevation at the International Standard Atmosphere.
Max/Avg Wind Speed (Air Velocity)One-button clear and restart of Max Wind Gust and Average Wind measurement.
Data Storage / DisplayMinimum, maximum, average and logged history stored and displayed for every measured value. 1792-point data logger with graphical display. Auto data storage; interval settable from 2 seconds to 12 hours. Manual data capture.
Data UploadRequires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available.
DisplayMultifunction, multi-digit programmable dot-matrix display.
Display Update1 second.
Display BacklightAviation green electroluminescent backlight. Automatic or manual activation.
Clock / CalendarReal-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Operational Temperature Range
(LCD and Batteries)
The operational temperature range of the liquid crystal display and batteries is 14° F to 131° F / -10 °C to 55 °C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading.
Storage Temperature-22 °F to 140 °F / -30 °C to 60 °C.
Auto ShutdownUser-selectable: 15 or 60 minutes with no key presses or disabled.
LanguagesEnglish, French, German, Italian, Spanish.
CertificationsCE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).
BatteriesAAA Alkaline, two, included. Average life, 400 hours of use, +/-depending on backlight use.
EnvironmentalWaterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.).
DimensionsUnit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm.
WeightUnit 3.6 oz / 102 g

PC Interface for Kestrel 4000 Models

PC Interface for Kestrel 4000 Models

With the Kestrel Interface and Communicator Software, data can be uploaded for long-term storage, in-depth analysis and detailed charting. The NEW...
Replacement Battery Door

Replacement Battery Door

Replacement Battery Door - Please select the appropriate model. Some of the 4000 Series may require a special order (upto 15 working days - normally...
Replacement Covers

Replacement Covers

Replace your original lost or damaged cover with this original factory replacement part - available for any Kestrel model/color.
Spare Impeller (Easy User Install)

Spare Impeller (Easy User Install)

Replacement impeller for all Kestrel models. Simply presses out, no tools required to change.
Tripod Large for Kestrel Meters

Tripod Large for Kestrel Meters

New for Spring 2008! A tripod fitted with the same Kestrel friendly clamp as on our mini tripod. Will accommodate any Kestrel model. Or remove the...
Tripod Small

Tripod Small

Clamp any Kestrel into this sturdy but lightweight tripod to take readings in the field. The tripod?s legs extend to permit a maximum height of 10",...
Vane Mount For All Models

Vane Mount For All Models

The Kestrel Portable Vane Mount is an ingeniously simple accessory designed for extreme light weight and portability. The Vane Mount assembles in...
Carry Case (Black)

Carry Case (Black)

This sturdy padded nylon case lets you build a Kestrel 4000 Toolkit perfect for your needs and still carry it on your belt with ease. The top flap...
Relative Humudity Calibration Kit

Relative Humudity Calibration Kit

The RH calibration kit includes the following items: three clear, sealable containers one container with magnesium chloride solution one container...



This product was added to our catalog on Thursday 16 July, 2009.

Customers who bought this product also purchased...