Choose Country: English  
Currencies:
The Kestrel Pocket Weather Meters in use
Kestrel Weather Australia
Home Page
New Products
Your login or register page
Shopping Cart
Contact Us
Special
Create Account
Customor Login
  Quick Search
 Advanced Search
Your Shopping Cart
in your cart 0 ITEMS

Kestrel Weather Australia - Ph: 03 9005 1708

 
 

Kestrel 4500 Pocket Weather Meter

Price: $689.00

Price: $689.00

Inc GST

Please Choose:



Add to Cart:


Currency Converter Services




For years our customers have been asking for wind direction along with wind speed. New for 2007, the Kestrel 4500 does just that with its built in digital compass. But it doesn’t stop there. It also calculates crosswind and headwind/tailwind with reference to a user-set target heading, and stores the information along with all the other environmental readings in its 1400 data point memory.

Pair the 4500 Wind Meter with the Kestrel Vane Mount and you have a data-logging weather station that sets up in seconds and rotates in the slightest of breezes. Did we mention that the whole kit is the ultimate in portability? It packs down into a 2 x 6 inch pouch and weighs under 8 ounces.

Available in the NV Configuration

Military personnel and pilots flying in darkness are often concerned with preserving their night vision. Due to overwhelming demand from our military customers, the Kestrel NV line was added in 2005.

The Kestrel 4000NV is available with an Olive Drab case or a Desert Tan case. The unit has a night-vision preserving backlight which helps users to sustain natural night vision. The NV's backlight incorporates an optical filter to reduce overall brightness and minimize blue and green spectrum light to preserve night vision. Additionally, NV backlights are also much dimmer than a standard backlight, making it more difficult to detect with the naked eye in night operations. This backlight appears soft greyish pink, not red, and is still in the visible spectrum, so is not compatible with night-vision equipment.

It takes 30 to 45 minutes for the average eye to adapt to darkness and maximize night vision. Even a short burst of white, yellow, green or blue light “bleaches out” the rod cell photoreceptors in the eye and causes night blindness until the entire adaptation process can take place again. Light in the red spectrum does not cause this “bleaching out”, preventing night blindness and night vision fatigue.



Kestrel Pocket Weather Meter Accessories - Click Here

Kestrel 4500 Measures

  • Heading (true & magnetic)
  • Wind direction
  • Crosswind
  • Headwind/tailwind
  • Altitude
  • Pressure trend
  • Barometric pressure
  • Wet bulb temperature
  • Relative humidity in %
  • Heat stress index
  • Dewpoint
  • Wet bulb temperature
  • Density altitude
  • Wind chil
  • Air, water, and snow temperature °F or °C
  • Current, average, and maximum air velocity

Kestrel 4500 Features

  • Waterproof and floats
  • Time and date
  • Easy- to-read backlit display
  • Data Logger (automatic and manual)
  • Customizable data storage - 1400 data points
  • Minimum, Maximum and Average values
  • Multi-Function 3-line display
  • Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit.
  • Exterior temperature, humidity, and pressure sensors for fast and accurate readings
  • Customize screens to display user-selected measurements
  • Graph and recall trends
  • User-replaceable impeller
  • Flip-top impeller cover allows use of other functions while protecting the impeller
  • Data charting
  • Upload to a computer (with optional interface)
  • Five languages (English, French, Spanish, German, and Italian)
  • US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074
  • 5-year warranty
  • Assembled in the USA

Kestrel 4500 Includes

  • Soft carry pouch
  • Neck lanyard
  • Batteries - 2 AAA
  • Kestrel Certificate of Conformity

Measurement
Response Time
UnitsOperational RangeResolutionAccuracy
(+/-)
Specification Range
Wind Speed
1 second
m/s0.4 to 60.0 m/s0.1Larger of 3% of reading or least significant digit0.4 to 40.0 m/s
ft/min59 to 11,948 ft/min159 to 7877 ft/min
km/h1.0 to 218.0 km/h0.11.0 to 144.0 km/h
mph0.8 to 135.0 mph10.8 to 89.0 mph
knots0.6 to 118.3 kt0.10.6 to 78.0 kt
Beaufort0 to 12 B0.10 to 12 B
1 inch diameter impeller with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may cause destruction of impeller. Replacement impeller (NK PN-0801) may be field-installed without tools (US Patent 5,783,753).
Wind Direction / Forward Heading
1 second
°360°10 to 360°
Cardinal Points360°16 Points0 to 360°
2-axis solid-state magnetoresistive sensor mounted perpendicular to unit plane to permit operation while measuring wind speed. Declination/variation adjustable for True North readout. Accuracy of measurements dependent upon unit's vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power-down (battery removal or change).
Temperature
1 second
°F-49.0 to 257.0 °F0.11.8 °F-20.0 to 158.0 °F
°C-45.0 to 125.0 °C0.11.0 °C-29.0 to 70.0 °C
Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible.
Relative Humidity
1 minute
%RH0.0 to 100.0 %0.13.0 %RH 5.0 to 95.0 % non-condensing
Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.) Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802).
Pressure
1 second
(mb & PSI 4000 model only)
inHg0.3 to 32.5 inHg0.010.05 inHgAt 77.0 °F, 22.1 to 32.5 inHg
hPa / mb10.0 to 1100.0 hPa / mb0.11.5 hPa / mbAt 25.0 °C, 750 to 1100 hPa / mb
PSI0.15 to 16.0 PSI0.010.02 PSIAt 77.0 °F, 10.9 to 16.0 PSI
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature range 32 to 158 °F (0 to 70°C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03 inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory or in field.
Altitude
1 second
ft-6000 to 30000 ft150 ftAt 77.0 °F, <19,700 ft. Max error +/- 98 ft
m-2000 to 9000 m115 mAt 25.0 °C, <6,000 m. Max error +/- 30 m
Temperature compensated pressure (barometric) altimeter.
Crosswind
Headwind, Tailwind

1 second
mph0.8 to 135.0 mph15%8.5 to 89.0 mph
ft/min59 to 11,880 ft/min15%750 to 7832 ft/min
km/h1.0 to 217.3 km/h0.15%13.7 to 143.2 km/h
m/s0.4 to 60.0 m/s0.15%3.8 to 40.0 m/s
knots0.6 to 117.3 kt0.15%7.4 to 77.0 kt
Calculated from the primary measurements of wind speed, wind direction and target heading. Auto-switching headwind/tailwind indication. Ranges expressed refer to primarywind speed.
Wind Chill
1 second
°F0.7 to 135.0 MPH, -49.0 to 257.0 °F0.11.8 °F1.8 to 89.0 mph, -50.0 to 50.0 °F
°C0.4 to 60.0 m/s, -45.0 to 125.0 °C0.11.0 °C0.4 to 40 m/s, -45.6 to 10.0 °C
Calculated from the primary measurements of wind speed and temperature. Utilizes the NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground. (Specification temperature limits established by WCT Tables.)
Heat Index
1 minute
°F0.0 to 100.0 %RH, -49.0 to 257.0 °F0.13.6 °F70.0 to 130.0 °F, 0 to 100% RH
°C0.0 to 100.0 %RH, -45.0 to 125.0 °C0.12.0 °C21.1 to 54.4 °C, 0 to 100 %RH
Calculated from the primary measurements of temperature and relative humidity. Utilizes the NWS Heat Index (HI) tables. (Specification temperature limits established by HI tables.)
Dewpoint
1 minute
°F0.0 to 100.0 %RH, -49.0 to 257.0 °F0.13.6 °F-20.0 to 158.0 °F, 20.0 to 95.0% RH
°C0.0 to 100.0 %RH, -45.0 to 125.0 °C0.12.0 °C-29.0 to 70.0 °C, 20.0 to 95.0 %RH
Calculated from the primary measurements of temperature and relative humidity. Temperature to which the air would need to be cooled at a constant pressure to become saturated.
Wet Bulb Temperature
1 minute
°F-49.0 to 257.0 °F, 0.0 to 100.0 %RH, 8.86 to 32.48 inHg0.13.6 °F32.0 to 100.0 °F, 5.0 to 95.0% RH, 8.86 to 32.48 inHg, <19700 ft
°C-45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa0.12.0 °C0.0 to 37.8 °C, 5.0 to 95.0 %RH, -2000.0 to 9000.0 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Temperature indicated by a wet bulb psychrometer.
Density Altitude
1 second
ft-49.0 to 257.0 °F, 0.0 to 100.0 % RH, 8.86 to 32.48 inHg124632.0 to 100.0 °F, 5.0 to 95.0 %RH, 8.86 to 32.48 inHg, <19700 ft
m-45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa1750.0 - 37.8 °C, 5.0 to 95.0 %RH, -2000 to 9000 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Air density converted to equivalent sea level elevation at the International Standard Atmosphere.
Max/Avg Wind Speed (Air Velocity),
Crosswind, Headwind/Tailwind
One-button clear and restart of Max Wind Gust and Average Wind measurement.
Data Storage / DisplayMinimum, maximum, average and logged history stored and displayed for every measured value. 1400-point data logger with graphical display. Auto data storage; interval settable from 2 seconds to 12 hours. Manual data capture.
Data UploadRequires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available.
DisplayMultifunction, multi-digit programmable dot-matrix display.
Display Update1 second.
Display BacklightChoice of aviation green or visible red electroluminescent backlight. Automatic or manual activation.
Clock / CalendarReal-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Operational Temperature Range
(LCD and Batteries)
The operational temperature range of the liquid crystal display and batteries is 14° F to 131° F / -10 °C to 55 °C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading.
Storage Temperature-22 °F to 140 °F / -30 °C to 60 °C.
Auto ShutdownUser-selectable: 15 or 60 minutes with no key presses or disabled.
LanguagesEnglish, French, German, Italian, Spanish.
CertificationsCE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).
BatteriesAAA Alkaline, two, included. Average life, 400 hours of use, +/-depending on backlight use.
EnvironmentalWaterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.).
DimensionsUnit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm.
WeightUnit 3.6 oz / 102 g.

PC Interface for Kestrel 4000 Models

PC Interface for Kestrel 4000 Models

With the Kestrel Interface and Communicator Software, data can be uploaded for long-term storage, in-depth analysis and detailed charting. The NEW...
Replacement Battery Door

Replacement Battery Door

Replacement Battery Door - Please select the appropriate model. Some of the 4000 Series may require a special order (upto 15 working days - normally...
Replacement Covers

Replacement Covers

Replace your original lost or damaged cover with this original factory replacement part - available for any Kestrel model/color.
Spare Impeller (Easy User Install)

Spare Impeller (Easy User Install)

Replacement impeller for all Kestrel models. Simply presses out, no tools required to change.
Tripod Large for Kestrel Meters

Tripod Large for Kestrel Meters

New for Spring 2008! A tripod fitted with the same Kestrel friendly clamp as on our mini tripod. Will accommodate any Kestrel model. Or remove the...
Tripod Small

Tripod Small

Clamp any Kestrel into this sturdy but lightweight tripod to take readings in the field. The tripod?s legs extend to permit a maximum height of 10",...
Vane Mount For All Models

Vane Mount For All Models

The Kestrel Portable Vane Mount is an ingeniously simple accessory designed for extreme light weight and portability. The Vane Mount assembles in...
Carry Case (Black)

Carry Case (Black)

This sturdy padded nylon case lets you build a Kestrel 4000 Toolkit perfect for your needs and still carry it on your belt with ease. The top flap...
Relative Humudity Calibration Kit

Relative Humudity Calibration Kit

The RH calibration kit includes the following items: three clear, sealable containers one container with magnesium chloride solution one container...



  • Model: k4500
  • Shipping Weight: 0.5kgs



This product was added to our catalog on Thursday 16 July, 2009.


 
 
 
 

We Accept ...







Shipping & Returns | Privacy Notice | Conditions of Use | Contact Us | Specials | Reviews
Designed by JR Web Solutions (03) 5309 3973